Signals

Input and output
The input signals can be used by the machine controller to activate the following power
signals
source functions
-
The power source can use the output signals to transfer the following feedback signals to
the machine controller
-

Signal waveform

No.
(1)
(2)
(3)
(4)
(5)
"Welding on" signal = start welding process
The "Process active" signal indicates whether the welding process is stable during
welding operation.
During touch operation, the signal indicates whether the workpiece has been touched.
1
(1)
0
1
0
Description
Input signal "Welding on"
"Process active" output signal
Gas pre-flow time
Welding current
Gas post-flow time
(3)
(4)
(2)
(5)