STEP-BY-STEP OPERATION:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement. Another command causes the gate to start moving again in the
opposite direction.
Step-by-step 1 operations:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement during both opening and closing. Another command causes the
gate to start moving again in the opposite direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands. The selection of this type of operation is
described in Pause time programming mode.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453.
DS1 input (NC)
Tripping of the photocells during opening is disregarded, while during
closing it causes reversal of the direction of movement.
DS2 input (NC)
Tripping during opening causes momentary stopping of the gate; once the
safety is freed the control unit resumes the opening movement. Tripping
during closing causes reversal of the direction of movement. To allow
operation in compliance with EN 13849-1 Category 2 a photocell test is
performed before each movement. The control unit enables the movement
only if the test is passed; if it is not, the control unit inhibits all movements
and an alarm condition is signalled by blinking of all the programming LEDs
on transmission of each command.
OPERATOR FORCE ADJUSTMENT (FORCE):
The electronic control unit is equipped with a "FORCE" trimmer for
adjustment of the force delivered by the operators, completely managed by
the microprocessor. Adjustment can be performed in a range of between
50% and 100% of maximum force. Initial starting torque can be set for each
movement by feeding the operators at full power for 2 seconds, even if
operator force control is enabled. Note: initial starting torque is disabled
automatically if the Soft Start function is enabled.
IMPORTANT: If the "FORCE" trimmer is adjusted the learning
procedure must be repeated because the movement and
deceleration times may change.
DECELERATION (SLOW):
The operators deceleration function is used on gates to prevent the moving
leaves from slamming at speed into the limit stops at the end of the opening
and closing strokes. During Motor Time programming (see Main menu) the
control unit also allows programming of deceleration in the desired positions
(before total opening and closing). If the "Automatic Programming" function
is used (see extended menu 1) it is still possible to include a deceleration
stage only for the first 4 seconds of the movement.
OPERATION WITH TIMER:
The control unit allows a timer to be connected in place of the open – close
pushbutton. E.g.: at 08.00 am the timer closes the contact and the control
unit commands an opening movement; at 06.00 pm the timer opens the
contact and the control unit commands a closing movement. From 08.00
am – 06.00 pm at the end of the opening cycle the control unit disables the
flashing light, automatic closing and the remotes.
ELECTRIC LOCK CONTROL OUTPUT:
The control unit features a voltage-free output contact to power an electric
lock. The contact is closed at each initial opening movement for a period
of 2 seconds.

PROGRAMMING:

SELECT key: selects the type of function to store; the selection is indicated
by blinking of the LED.
Press the key twice to go to the desired function. The selection remains
active for 10 seconds shown by blinking of the LED; when this interval
elapses the control unit returns to the original state.
SET key: programs the information in accordance with the function type
preselected with the SELECT key.
IMPORTANT: the SET key function can be replaced by the remote if
programmed beforehand.
Programming enabled only when safety devices are not active.
L1
DELAY
Operator 1 delay
L2
STEP-BY-STEP
Step-by-Step
L3
TX CODE
Code entered
L4
CONDO
L5
MOTOR TIME
Programmed time
L6
PAUSE TIME
With automatic closing
L7
PED. TIME
LEV
MENU
MAIN MENU
The control unit is factory set to allow the selection of several important
functions.
1. DELAY:
In the default configuration the control unit is set up with "OPERATOR 2
DELAY" logic. To avoid having to disconnect the wiring in order to set a
delay for operator 1 rather than operator 2, proceed as follows: use the
SELECT key to select blinking LED L1 and then press the SET key: LED
L1 becomes steady on and programming will be completed. Repeat the
procedure if you want to restore the previous configuration.
2. STEP BY STEP:
In the default configuration the control unit is set with "Automatic" operating
logic enabled (LED n2 off); if the "Step-by-Step" operating logic is required
(LED n2 on), proceed as follows; use the SELECT key to select blinking
LED n2 and then press the SET key: LED n2 becomes steady on and
programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to obtain
the quick blinking of LED. Repeat the procedure if you wish to restore the
previous configuration.
3. TX CODE (Remote control code):
Up to 120 remotes with different codes, either of the fixed or the rolling
code type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L3. Press SET once; the LED will change
its blinking mode (longer 1 0 1 0) to show that the first level is being saved.
On sending the selected code with the desired remote, the LED will remain
steady on to indicate that programming has been completed. To save
the code for pedestrian opening / single leaf proceed as follows: use the
SELECT key to select blinking LED L3. Press SET twice consecutively; the
LED will change its blinking mode (1 1 0 1 1 0) to show that the pedestrian
code is being saved. On sending the selected code with the desired
remote LED L3 will remain steady on to indicate that programming has been
completed. If all 120 codes have been saved, repeating the programming
operation will cause all the programming LEDs to start blinking, to signal that
no further codes can be saved.
Deletion:
Use SELECT to go to LED L3; activate blinking of the code to be deleted
(CODE or PEDESTRIAN identified by the respective blinking); press and
hold down SET for > 5 s. After this interval the LED will switch off for 2
seconds and the procedure is completed. If all CODE and PEDESTRIAN
codes are deleted, the LED will remain off. If only PEDESTRIAN codes
remain stored, the LED blinking mode will change (1 1 1 1 0 1 1 1 1 0).
COMUNELLO ®Copyright 2014 - All right reserved
Operator 2 delay
Automatic
No code
ON
OFF
30 sec.
Without automatic closing
ON
OFF
ON
19