BIAS
The mini GAC uses the same grain constants as the
DICKEY-john federal standard GAC2100 and is calibrated to
USDA certification.
In situations where moisture or test weight differences occur with
a local elevator, the Bias function allows entering of a correction
factor in moisture and test weight to compensate for those
differences.
IMPORTANT:
Test Weight does not display on the mini
GAC model.
To change the Moisture or Test Weight Bias setting:
1. From the Home menu, press the Down Arrow button and
scroll to Bias and press Enter.
2. Press the Up or Down Arrow button to select either
Moisture or Test Weight.
3. Press the Up or Down Arrow to increase/decrease the
bias percentage.
4. Press the Enter button to save the changed setting or the
On/Off/Home button to escape and retain the previous
setting.
Figure 18
Modifying Moisture or Test Weight Bias
Soybeans
Average
Bias
Moisture Bias
Bias Adjustment