Lower exhaust flue
• Insert the wooden profile 20 (optional) between the hood body
and the flue.
• Fix the lower section of the flue and the cable raceway to the
hood body from above, using the 6 screws 12g provided.
Upper exhaust flue
• Slightly widen the two sides of the upper flue and hook them
behind the brackets 7.2.1, making sure that they are well seat-
ed.
• Secure the sides to the brackets using the 4 screws 12c sup-
plied.
Mounting the hood body
At the discretion of the fitter, the wall corner panel can be in-
stalled by screwing it to the back of the hood using the three 12b
screws provided.
• Adjust the two screws Vr, on brackets 11a, to a minimum.
• Hook the hood canopy onto the two brackets 11a.
• Remove the filters, one at a time, after disconnecting the rela-
tive fastening elements.
• From inside the hood canopy, adjust the screws Vr to set the
Hood Canopy level.
• Fix the hood to the wall using the two safety holes located at
the bottom inside the canopy of the hood (wall plugs 11 +
screws 12a).
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the reduc-
er flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
EN
Flue assembly
Connections
12g
2.2
2.1
11a
ø 150
ø 120
20
12c
Vr
9
1
10
0