INSTALLATION
12a
11a
Wall marking:
• Draw a horizontal line at 650 mm above the hob.
• Mark a reference point at 356 mm from the corner of the wall and 458 above the horizontal
reference line as shown.
• Repeat the operation for the opposite side and check levelling.
• Drill at the points marked, using a ø 12 mm drill bit.
• Insert the bracket plugs 11a into the holes and screw into place.
• Mark a reference point at 1-2 mm below the ceiling or top limit and at 341 mm from the
corner of the wall as shown. Repeat the operation for the opposite side and check levelling.
• Drill at the points marked, using a ø 8 mm drill bit.
• Insert the wall plugs 11 in the holes.
• Fix the brackets using the 12a screws (4,2 x 44,4) supplied.
• Mark a reference point at 185 mm below the newly fixed bracket and at 341 mm from the
corner of the wall as shown. Repeat the operation for the opposite side and check levelling.
• Drill at the points marked, using a ø 8 mm drill bit.
• Insert the wall plugs 11 in the holes.
• Fix the brackets using the 12a screws (4,2 x 44,4) supplied.
EN
Wall drilling and bracket fixing
11
341
341
356
356
9