Reducing fan power.
Press the symbol Reduce fan power.
The fan power is reduced by one level
each time the field is pressed until level
1 is reached.
Lighting
Press the button with the lighting symbol
to switch on the lighting. The lighting is
switched off by pressing the button
again. The lighting is dimmed by press-
ing and holding the lighting symbol.
lighting is not dimmable
Intensive level
Maximum fan power is reached by
pressing the button Intensive level. The
fan power switches back by one level
after 5 minutes.
Automatic follow-up time
The automatic follow-up time is acti-
vated by pressing the field with the Fol-
low-up time symbol (2
left). The follow-up time symbol lights
up. The extractor hood switches from
level 3 back top level 1 and runs at this
level ~15 minutes before switching off.
Room ventilation
Pressing (10sec.) the clock symbol but-
ton activates/deactivates the room ven-
tilation function.
Changing the batteries:
The battery cover is situated on the
back of the remote control. Lift the cover
with thumb and first finger until the mag-
netic contact that holds the battery cover
releases. Now remove the empty batter-
ies and replace them with new batteries
of the same type. Caution: Do not dis-
pose of empty batteries with your nor-
mal household waste!
Technical data
Dimensions: 230 x 34 x 10
Battery: 2 lithium batteries
Type: CR 2032 3 V
Infrared range: ~ 2 m
LED
nd
symbol from the
Operation via Switch
is an emergency function, not all func-
tions are available)
The control panel Located on the Ceiling
Device below the Pane. The control
panel consists of 2 buttons with 6 LED's.
The exhaust power is controlled over
the switch panel. Among the lighting
additional options are also controlled
over the switch panel by some extractor
hoods.
Pressing the switch to the left: Light ON/
OFF
Pressing the switch to the right: Regula-
tion of the power level
Pressing the switch to the right for 3
seconds: hood is turned off.
The filter saturation display is also reset
using this switch. To do so, press the
switch to the right until the red LED
turns off.
LED Indicators
Information regarding the operating con-
ditions of the hood can be read on the
device's LED indicators:
Indicators
Cool Down
Level 1
Level 2
Level 3
Intensive Level
Filter Saturation Indicator
LED 1: Indicates operational status ON/
OFF
en
-
+
green LED
green LED
green LED
green LED
green LED
red LED
31