GB
IRL
5.2 Micro-filters
The degree of clogging of the filter mats should be checked
at regular intervals, depending on the ambient conditions/
conditions of use, i.e. the user is responsible for ensuring that
the filters are permeable.
6 List of spare parts
6.1 Housing positions
It is essential to state the housing position when ordering spare
parts. The blower position can be identified from the name plate
or from the diagrams below. Order the spare parts to suit the
rotational direction.
Anti-clockwiese rotation = El to Hl
El
Fl
Gl
Hl
7 EC Manufacturer Declaration
Elektror
airsystems gmbh
Richard-Hirschmann-Strasse 12, D-73728 Esslingen/Neckar
Postfach 10 02 51, D-73702 Esslingen/Neckar
We certify on our sole responsibility that the product to which this certificate relates, is in conformity with the standards or
standard-setting documents listed below.
If a modification of the unit(s) is made without our consent, this certificate becomes invalid.
Description of the machine:
Low-pressure blower type D 052M, E 052, D 060M, E 060
Relevant regulations to which this machine corresponds:
EC machine directives (98/37/EC)
Low-voltage directive (73/23/EEC f.)
Source references of harmonised standards:
DIN EN 292, Safety of machines, basic terms, general configuration directives;
Part 1: Basic terminology, methodology – Part 2: Technical principles and specifications
EN 60034-1 (DIN VDE 0530 Part 1), Rotating electrical machines;
EN 60034-5 (DIN VDE 0530-5), Classification of degrees of protection provided by enclosures for rotating machinery
DIN EN 60204, Safety of machinery; electrical equipment of machines
Part 1: General requirements (Electric motors)
Source references of national standards:
DIN VDE 0110-1, Insulation co-ordination for equipment within low-voltage systems;
Part 1: Basic principles, requirements and tests
Starting operation of this machinery part is not allowed as long as it is not assembled into the main installation respec-
tively not all necessary safety devices have been installed which fulfill the requirements of the EC directive for machines
with regard to safety and health.
Kreher (Managing director)
Esslingen, 02.10. 2006
8
☛
Note!
Repairs must be carried out by the manufacturer
only. We cannot accept any liability for repairs
carried out by third parties.
6.2 When ordering please state
☛
Note!
G Serial no. (rating plate)
G Blower Type (rating plate)
G Part No. and/or item no. (spare parts list)
Clockwise rotation = Ar to Dr
Ar
Br
Cr
Dr