8.4. Function selection
<Wired remote controller type>
(1) Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed.
Item 1
1. Change Language
Language setting to display
("CHANGE LANGUAGE")
2. Function limit
(1) Operation function limit setting (operation lock) ("LOCKING FUNCTION")
("FUNCTION
(2) Use of automatic mode setting ("SELECT AUTO MODE")
SELECTION")
(3) Temperature range limit setting ("LIMIT TEMP FUNCTION")
3. Mode selection
(1) Remote controller main/sub setting ("CONTROLLER MAIN/SUB")
("MODE SELECTION")
(2) Use of clock setting ("CLOCK")
(3) Timer function setting ("WEEKLY TIMER")
(4) Contact number setting for error situation ("CALL.")
(1) Temperature display °C/°F setting ("TEMP MODE °C/°F")
4. Display change
("DISP MODE SETTING")
(2) Suction air temperature display setting ("ROOM TEMP DISP SELECT")
(3) Automatic cooling/heating display setting ("AUTO MODE DISP C/H")
[Function selection flowchart]
[1] Stop the air conditioner to start remote controller function selection mode. → [2] Select from item1. → [3] Select from item2. → [4] Make the setting. (Details
are specified in item3) → [5] Setting completed. → [6] Change the display to the normal one. (End)
Normal display (Display when the
air condition is not running)
(Hold down the E button and press the D button for two
seconds.)
* The display cannot be changed during the unit function
selection, the test run and the self diagnosis.
Item 1
Press the G button.
Change Language
("CHANGE LANGUAGE")
Press the E
→
button.
Function limit
("FUNCTION
Press the
SELECTION")
G button.
Press the
Press the
E button.
E button.
→
Press the
Mode selection
G button.
("MODE
SELECTION")
Press the
E button.
→
Press the
Display change
G button.
("DISP MODE
SETTING")
[Detailed setting]
[4] -1. CHANGE LANGUAGE setting
The language that appears on the dot display can be selected.
•
Press the [
MENU] button to change the language.
1 Japanese (JP), 2 English (GB), 3 German (D), 4 Spanish (E), 5 Russian
(RU), 6 Italian (I), 7 Chinese (CH), 8 French (F)
[4] -2. Function limit
(1) Operation function limit setting (operation lock)
• To switch the setting, press the [
1 no1: Operation lock setting is made on all buttons other than the [
button.
2 no2: Operation lock setting is made on all buttons.
3 OFF (Initial setting value):
Operation lock setting is not made.
* To make the operation lock setting valid on the normal screen, it is necessary to
press buttons (Press and hold down the [FILTER] and [
the same time for two seconds.) on the normal screen after the above setting is
made.
(2) Use of automatic mode setting
When the remote controller is connected to the unit that has automatic operation
mode, the following settings can be made.
• To switch the setting, press the [
1 ON (Initial setting value):
The automatic mode is displayed when the operation mode is selected.
2 OFF:
The automatic mode is not displayed when the operation mode is selected.
10
Item 2
Remote Controller Function
Selection Mode
Item 2
Operation function limit setting ("LOCKING FUNCTION")
Use of automatic mode setting ("SELECT AUTO MODE")
Temperature range limit setting ("LIMIT TEMP FUNCTION")
Remote controller main/sub setting ("CONTROLLER MAIN/SUB")
Use of clock setting ("CLOCK")
Timer function setting ("WEEKLY TIMER")
Contact number setting for error situation ("CALL.")
Temperature display °C/°F setting ("TEMP MODE °C/°F")
Suction air temperature display setting ("ROOM TEMP DISP SELECT")
Automatic cooling/heating display setting ("AUTO MODE DISP C/H")
ON/OFF] button.
ON/OFF]
ON/OFF] buttons at
ON/OFF] button.
• Display in multiple languages is possible.
• Setting the range of operation limit (operation lock)
• Setting the use or non-use of "automatic" operation mode
• Setting the temperature adjustable range (maximum, minimum)
• Selecting main or sub remote controller
* When two remote controllers are connected to one group, one controller must be set to sub.
• Setting the use or non-use of clock function
• Setting the timer type
• Contact number display in case of error
• Setting the telephone number
• Setting the temperature unit (°C or °F) to display
• Setting the use or non-use of the display of indoor (suction) air temperature
• Setting the use or non-use of the display of "Cooling" or "Heating" display during
operation with automatic mode
(Hold down the E button and press
the D button for two seconds.)
* The remote controller records the
setting that is made in this way.
See [4]-1
(Setting content)
See [4]-2. (1)
Press the D
Press the G button.
button.
See [4]-2. (2)
See [4]-2. (3)
Press the D
button.
See [4]-3. (1)
Press the G button.
See [4]-3. (2)
See [4]-3. (3)
See [4]-3. (4)
Press the D
button.
See [4]-4. (1)
Press the G button.
See [4]-4. (2)
See [4]-4. (3)
(3) Temperature range limit setting
After this setting is made, the temperature can be changed within the set range.
• To switch the setting, press the [
1 LIMIT TEMP COOL MODE:
The temperature range can be changed on cooling/dry mode.
2 LIMIT TEMP HEAT MODE:
The temperature range can be changed on heating mode.
3 LIMIT TEMP AUTO MODE:
The temperature range can be changed on automatic mode.
4 OFF (initial setting): The temperature range limit is not active.
* When the setting, other than OFF, is made, the temperature range limit setting
on cooling, heating and automatic mode is made at the same time. However, the
range cannot be limited when the set temperature range has not changed.
• To increase or decrease the temperature, press the [
button.
• To switch the upper limit setting and the lower limit setting, press the [
button. The selected setting will flash and the temperature can be set.
• Settable range
Cooling/Dry mode: Lower limit: 19°C ~ 30°C
Heating mode:
Lower limit: 17°C ~ 28°C
Automatic mode:
Lower limit: 19°C ~ 28°C
* The settable range varies depending on the unit to connect (Mr. Slim units, Free-
plan units, and intermediate temperature units)
Item 3 (Setting content)
NOTE
Timer operation stops when the display for
remote controller function selection is changed
to the normal one.
Dot display
Item 3
The language that is selected in
CHANGE LANGUAGE mode
appears on this display. English is set
in this manual.
F
TEMP.
MENU
ON/OFF
E
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
G
C
ON/OFF] button.
TEMP (
Upper limit: 30°C ~ 19°C
Upper limit: 28°C ~ 17°C
Upper limit: 28°C ~ 19°C
ON/OFF
I
A
FILTER
CHECK
TEST
B
OPERATION
CLEAR
H
D
) or (
)]
]