Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to assist in
the identification and correction of any anomalies and
malfunctions which might occur during use.

Fault

The plates do not turn on
The control panel does not come
on.
TABLE OF ALARM INDICATIONS
Alarm
Er3
Er4
FAULT
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
Cause
Electrical connection not made
correctly.
Electronic circuit board not
receiving electrical power.
Electronic circuit board damaged.
Cause
Electronic circuit board
diagnostics tripped.
Electronic circuit board heat
sensor tripped.
The appliance switches to
stand-by status.
Fan malfunction.
The appliance switches to
stand-by status.
Air intake line blocked.
The appliance switches to
stand-by status.
- 11 -
Remedy
Check the connection of the
electrical wiring.
Important
Contact
the
after-sales
service.
Check the connection of the
electrical wiring.
Important
Contact the after-sales
service
Remedy
Replace the electronic circuit
board
Important
Contact
the
after-sales
service.
Allow the appliance to cool and re-
turn it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Important
Contact the after-sales servi-
ce.
Check the condition of the fan and
the electrical connections.
Clean the air intake lines
Important
If the problem persists, in-
form the After Sales Service.
6
IT
GB
DE
FR
ES
English

Publicidad

Tabla de contenido
loading