Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4. DISPLAY
The OLED display switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
- The main operational parameters of the tool processed by the circuit board, such as peak pres-
sure or force reached.
- Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
- Any operational or procedural ERRORS.
Use the touch button (6) to navigate through the menu
screens to manage INFORMATION AND SELECTION:

4.1) INFORMATION SCREENS:

appear each time the tool is started and during the entire work cycle.
F
= 125.2 kN
m
Fp = 94.5 kN
F
= 14.07 ton
m
Fp = 10.61 ton
P
= 692 bar
m
Pp = 522.3 bar
P
= 10037 psi
m
Pp = 7575 psi
BATTERY
1000
-12000
B1300
NR 14AF035
display a pre determined parameter which will then
Fm: Minimum set force, expressed in kN.
Fp: Peak force reached, expressed in kN,
(screen as factory setting)
Fm: Minimum set force, expressed in USA sh. tons.
Fp: Peak force reached, expressed in USA sh. tons.
Pm: Minimum set pressure, expressed in bar.
Pp: Peak pressure reached, expressed in bar.
Pm: Minimum set pressure, expressed in psi.
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
Tool serial no
F
= 125.2 kN
m
F
= 102.3 kN
p
P
= 692 bar
m
P
= 565 bar
p
max.
BATTERY
LED
ON
LED
OFF
8
F
= 125.2 kN
m
OK
P
= 692 bar
m
OK
min.
BATTERY
10
6
3 SEC.

Publicidad

Tabla de contenido
loading

Tabla de contenido