7. DISPLAY
The OLED display (8) switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
The main operational parameters of the tool processed by the circuit board, such as peak pres-
sure or force reached.
Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
Any operational or procedural ERRORS.
Use the touch button (7) to navigate through the menu screens to manage
INFORMATION AND SELECTION:

7.1) INFORMATION SCREENS:

time the tool is started and during the entire work cycle.
Fm: Minimum set force, expressed in kN.
F
= 125.2 kN
m
Fp: Peak force reached, expressed in kN,
Fp = 94.5 kN
(screen as factory setting).
F
= 14.07 ton
m
Fm: Minimum set force, expressed in USA sh. tons.
Fp = 10.61 ton
Fp: Peak force reached, expressed in USA sh. tons.
P
= 692 bar
m
Pm: Minimum set pressure, expressed in bar.
Pp = 522.3 bar
Pp: Peak pressure reached, expressed in bar.
P
= 10037 psi
m
Pm: Minimum set pressure, expressed in psi.
Pp = 7575 psi
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
BATTERY
10
No. of cycles performed.
-14990
No. of cycles before scheduled recommended maintenance.
B1300
Cembre logo, tool model.
15AA190
Tool serial no.
display a pre determined parameter which will then appear each