4. DISPLAY
The OLED display switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
- The main operational parameters of the tool processed by the circuit board, such as
peak pressure or force reached.
- Information on the condition of the tool, such as the charge level, the battery tem-
perature and maintenance requirements.
- Any operational or procedural ERRORS.
Use the touch button (8) to navigate through the menu screens to manage INFORMATION AND
SELECTION:
4.1) INFORMATION SCREENS:
appear each time the tool is started and during the entire work cycle.
F
= 125.2 kN
m
Fp = 94.5 kN
F
= 14.07 ton
m
Fp = 10.61 ton
P
= 692 bar
m
Pp = 522.3 bar
P
= 10037 psi
m
Pp = 7575 psi
BATTERY
1000
-12000
B1300
NR 14AF035
display a pre determined parameter which will then
Fm: Minimum set force, expressed in kN.
Fp: Peak force reached, expressed in kN,
(screen as factory setting)
Fm: Minimum set force, expressed in USA sh. tons.
Fp: Peak force reached, expressed in USA sh. tons.
Pm: Minimum set pressure, expressed in bar.
Pp: Peak pressure reached, expressed in bar.
Pm: Minimum set pressure, expressed in psi.
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
Tool serial no