Installation requirements
Location requirements
Clearances and dimensions
BEFORE YOU BEGIN to install this appliance,
refer to the following information,
dimensions, and clearances. Do not
locate the range where it may be subject
to strong drafts. Provide adequate
clearances between the range and adjacent
combustible surfaces. These dimensions
must be met for safe use of the range.
The location of the electrical outlet and
gas piping may be adjusted to meet the
following dimensions and clearances.
Side Clearance
Above Cooking
Surface to Wall
(61 cm)
36 in
(91.4 cm)
Cabinet
CAUTION
DO NOT install the oven so that the door is flush with the cabinet.
For OTR over Gas Stove, please follow local GAS CODE.
30 in
(76.2 cm)
6 in
4 in
(15.2 cm)
(10.2 cm)
24 in
Lower
Depth
For installation in Canada, a free-standing
range is not to be installed closer than 4.7 in
(12 cm) from any adjacent surface.
CAUTION
This range has been designed to comply
with the maximum allowable wood cabinet
temperature of 194 °F (90 °C). Make sure
the wall covering, countertops, and cabinets
around the range can withstand the heat (up
to 194 °F [90 °C]) generated by the range. If
not, discoloration, delamination, or melting
may occur.
30 in
(76.2 cm)
30 in (76.2 cm)
18 in
(45.7 cm)
0 in (0 cm)
Clearance
23.2 in
Below
(58.9 cm)
Cooking Top
and at Rear
and Sides of
Range
13 in
(33 cm)
Overhead
Cabinet
Depth
0 in
(0 cm)