Installation instructions
Step 8. Convert to lp gas (optional)
All new gas ranges are shipped from the
factory set up to use natural gas. Any
Samsung gas range can be converted to use
LP gas. Refer to page 97 in the User Manual
to contact a qualified service technician.
The conversion process should only be
performed by a qualified LP gas installer.
Conversion instructions and LP orifices will
be supplied with the LP conversion kit. The
conversion to LP requires all burner orifices
to be changed (5 surface burners).
In addition, the nozzle on the gas pressure
regulator needs to be reversed. All replaced
orifices must be left with the consumer,
including the instructions and retrofit sizes
and orifice indication.
Checking the flame quality all burner after
converting to lp gas.
38 English
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (LP Gas [Propane] 10 in WCP)
Burner
BTU Rate
Location
RF
16500
LF
11500
RR
4000
LR
7500
CTR
7500
BAKE
15000
BROIL
14500
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (Natural Gas 5 in WCP)
Burner
BTU Rate
location
RF
22000
LF
15000
RR
5000
LR
9500
CTR
9500
Orifice Size
[mm]
In: 0.46/
Out: 0.83 (2 pcs)
1.04
0.62
0.83
0.83
1.15
1.12
Orifice size
[mm]
In: 0.85/
Out: 1.36 (2 pcs)
1.78
1.01
1.40
1.38