8
Troubleshooting
If a fault cannot be resolved by means of the ac-
tions described here, please refer to Weidmüller
Service.
8.1 Fault table
Fault
Machine will not start
Machine switches itself off
during operation
Increased scrap
2516390000/03/07.2018
Possible cause
No power supply
Filling level monitoring is active and
the starting switch has been addressed
briefly
Overload
Blade cuts into wire-end ferrule
Waste container is full
Stripping blade damaged or incorrectly
installed
Recommended action
► Check the power cable and the mains connec-
tions.
► Check fuses.
► Acknowledge the error by briefly tapping the
touch display.
► Insert the connector correctly.
► Switch the machine off.
► Remove the belt.
► Start the machine in inching mode (see sec-
tion 8.7).
► Move forwards or backwards.
► Check for further damage.
► Empty the waste container (see section 7.4).
► Check the seating of the stripping blade, then
correct or replace blade (see section 8.3).
47