26. electrical connections to a multi-zone system

Connect terminals 1-2-3 (common-normally closed - normally open) of connector cn1 to terminals 10-9-8 of the boiler
terminal block M2 (figure 18).
bOILER CARD
Figure 18
Connect the switch controlling those zones not controlled by the remote control in parallel to the "ta" terminals 1-2 of
terminal board M1 as shown in figure below. The zone controlled by the remote control is supplied by the zone 1 sole-
noid valve, as shown in figure 18.1.
The remote control automatically controls room temperature in its own zone.
Figure 18.1
iMportant: For a multi-zone system be sure that parameter F04 = 2 (as described in section 20).
inStructionS Pertaining to the inStaller
26.1 - relay card connection
RELAy CARD ACCESSORy
rELAY 2
rELAY 1
26.2 - connection of zones
2 zone
(room
1 zone
thermostat)
solenoid
valve1 zone
68
3 zone
N zone
(room
(room
thermostat)
thermostat)