Installation
Features
Comfort
Module
Number of
comfort zones
managed
Dimensions,
mm
H x L x D
Operative
ambient
°C
temperature
Operating
kg
weight
Power supply
V-ph-Hz
Recommended
main breaker
Electric heater
kW
element
Number of
auxiliary heating
steps
Heating and
cooling
Connection of
back-up boiler
Integrated hydraulic connection
Integrated hydraulic circuit
Pictures 4 and 4a shows the integrated hydraulic circuit of
the Comfort Module with and without kits.
Picures 4 and 4a refers to:
A Standard version (80HMA-M00)
B Standard version Plus Pump Kit
(80HMA-M00 + 80HMA-9003)
C Standard version Plus BPHE Kit
(80HMA-M00 + 80HMA-9004/5)
See pic. 4 and 4a:
1. Water inlet pipe from heat pump (1' male)
2. Water outlet pipe to heat pump (1' male)
3. Water inlet pipe from terminal (1' male)
4
80HMA
80HMA-M00
80HMA-M03
800 x 450 x 320 (see pic. 2 for details)
34
230-1-50
C6
C20
0
3
1 (external
1
boiler)
Yes
80HMA-M06
80HMA-T06
1
5 ÷ 30
35
C32
6
Yes
No
4. Water outlet pipe to terminal (1' male)
5. Buffer tank (10lt)
6. Automatic purge valve
7. Connection for boiler backup (only M0 version,
otherwise Electric heaters) (3/4' male)
8. Manometer
9. Flow switch
10. Security pressure relief valve (3 barg)
11. Discharge pipe for pressure valve
12. Buffer tank temperature sensor
13. Leaving water temperature sensor
14. Water drain valve
15. Expansion vessel
16. Water pump
17. Brazed plate heat exchanger
18. Drain pipe. Don't connect tap to this pipe. It used to
drain water from pressure release too
80HMA-T09
400-3-50
C16
C20
6
9
3