Device overview
1
1
Indicator diodes
2
Four screws for housing cover - access to connection compartment
3
Screwed cable glands
4
SubD socket, 25-pin - KB 900-... connection to the BCL 900i/MSC 900-...
Start-up
2
Assembly
Mounting via two housing bore holes for screws with a diameter < 4mm. A drilling
template as well as 2x self-tapping screws (4.0 x 45mm) incl. washers are included
in the scope of delivery.
NOTICE
Degree of protection IP 65 is achieved only if the connectors are screwed into
place or screwed cable glands are properly tightened!
3
Electrical connection
While establishing the electrical connection, disconnect the MA 900 from the volt-
age supply (remove the KB 900-...).
ATTENTION
Voltage supply only via BCL 900i / MSC 900!
Voltage is supplied to the MA 900 exclusively via the KB 900-... interconnection
cable through the BCL 900i bar code reader or through the MSC 900 modular
scanner controller.
Do not connect voltage to terminals +V and -V!
Terminals +V and -V are used to supply voltage to other connected devices, such
as encoders and optoelectronic sensors (trigger sensor, presence sensor).
EN
15