Leuze electronic MA 900 Manual De Uso página 17

Unidad de conexión modular para bcl 900i/msc 900
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
Connection of the BCL 900i bar code reader
The BCL 900i bar code reader is connected to the MA 900 via a KB 900-... inter-
connection cable with 17-pin M12 socket and 25-pin SubD connector. This inter-
connection cable is available in three lengths:
- KB 900-1000, 1m long, Part no. 50129764
- KB 900-3000, 3m long, Part no. 50129763
- KB 900-5000, 5m long, Part no. 50129765
Information on connecting multiple bar code readers (master/slave arrangements)
can be found in the operating instructions.
Connection of the MSC 900 modular scanner controller
The MSC 900 modular scanner controller is connected to the MA 900 via the
KB 900-1000 MSC interconnection cable (length 1m, part no. 50129766) with two,
25-pin SubD connectors.
Further information on connecting the MSC 900 modular scanner controller and
multiple bar code readers (scanner portal solutions) can be found in the operating
instructions.
Grounding the connected BCL 900i / MSC 900
A jumper on the circuit board of the MA 900 can be used to set how the housing of
the connected BCL 900i or MSC 900 is grounded.
Jumper
Grounding principle for BCL 900i / MSC 900
Housing connected to functional earth (factory setting)
Housing not connected to functional earth or GND
Housing connected to GND
Assignment of SubD socket, 9-pin (RS 232 auxiliary interface)
Pin
Designation
2
TX
3
RX
5
SGND
1, 4, 6, 7, 8, 9
n.c.
Function
Transmit data - RS 232 auxiliary interface
Receive data - RS 232 auxiliary interface
Signal ground - RS 232 auxiliary interface
not connected
EN
17

Publicidad

Tabla de contenido
loading

Tabla de contenido