Maintenance As Needed, or every six months minimum.
WARNING! Before removing grill, turn the electrical power off at the electrical panel
board (circuit breaker or fuse box). Lock or tag the panel board door to prevent someone
from accidentally turning the power on while you are working on the heater. Failure to do
so could result in serious electrical shock, burns, or possible death.
WARNING: Any other service not detailed in this Owner's Guide should be performed by an autho-
rized service representative.
1. It is important that you verify power has been turned off and no
power is going to the heater before proceeding. Circuit breakers
are often not marked correctly and turning the wrong breaker off
could mean electricity is flowing to the heater, even if the heater
does not appear to be working. If you are uncomfortable working
with electrical appliances, unable to follow these guidelines, or do
not have the necessary equipment, consult a qualified electrician.
2. Once you verify the power has been turned off correctly, pro-
ceed to the next step.
3. Remove thermostat knob (if any), screws and take off grill.
*CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED
Symptom
Problem
Breaker trips
1. Incorrect supply voltage.*
immediately
2. Overloaded circuit.*
upon energiz-
ing heater.
3. A short circuit exists in the supply
or heater wiring.*
4. Defective circuit breaker.*
Heater fan
1. Insufficient element temperature.
operates,
2. Incorrect supply voltage.*
but does not
3. Element has failed.*
discharge
4. (Model CST only) One of the
warm air.
heater units over temperature con-
trols must be reset.
Heater will
1. Heat loss from room is greater
not shut off.
than heater capacity.*
2. Defective thermostat.
3. Thermostat wired incorrectly to
heater.*
1. Dust, lint or other matter has
Heater
discharges
accumulated inside heater.
smoke or
2. Poor or loose electrical connec-
emits a burnt
tions.
odor.
Element
1. Defective motor or internal
heats for a
connection.*
moment with-
2. Fan or motor jammed.
out the fan
turning, then
immediately
stops heating.
Heater does
1. Thermostat set too low.
not run.
2. Heater has tripped the power
reset high-temperature control.
3. Heater has tripped the second-
ary over-temperature fuse.
4. Power not on at the circuit
breaker.
5. Broken or poorly connected
wire(s) to heater.
6. Defective thermostat.
Page 6
MAINTAINING YOUR HEATER
Troubleshooting Chart
ELECTRICAL SERVICE PERSONNEL.
1. Verify that supply voltage matches the heater rating.
2. The total amperage of all heaters on a branch circuit must not be more than
80% of the amperage rating of the circuit breaker and supply wire ratings. Use
a lower wattage heater, or reduce the number of heaters on the circuit.
3. Shorted supply or heater wires may be accompanied by severe sparking.
Inspect all supply and heater wiring insulation for damage. Do not reset the
circuit breaker until all electrical shorts have been repaired.
4. Replace the circuit breaker.
1. Allow a few moments for element to reach operating temperature.
2. Verify that supply voltage matches the heater rating.
3. Replace element.
4. CST models have two heating units with independent over-temperature
controls. One of the high-temperature manual power reset controls may trip
and cut power to one of the heating units, while the other remains running,
resulting in only half output. Reset the heater unit (see "Operating" section for
"Resetting the Manual Power Reset Limit Control").
1. Close doors and windows. Provide additional insulation, or install a higher
wattage heater or multiple heaters if necessary. (If your circuit is rated for more
capacity.)
2. Adjust thermostat to its lowest setting. If heater continues to run (allow two
minutes for the thermostat to respond), and room temperature is greater than
50˚; replace the thermostat.
3. Refer to thermostat documentation and correct wiring.
1. Clean heater (see "Maintenance" section above for instructions).
2. Turn off power at circuit breaker. Inspect all supply and heater wire connec-
tions to make sure nothing is loose or poorly connected. Secure or reconnect
all loose connections. Do not reset circuit breaker until all connections have
been checked and repaired.
1. Heater or fan motor requires replacement.
2. Remove obstruction and follow instructions in the "Operating" section for
"Resetting the Manual Power Reset Limit Control." Test heater operation. If
heater does not run, heater requires repair or replacement.
1. Adjust thermostat to a higher temperature until heater operates (see Problem
#6 if the problem persists).
2. Follow instructions in the "Operating" section for "Resetting the Manual Pow-
er Reset Limit Control." If room temperature is below 45˚, see "Reset Heater at
the Circuit Breaker" instructions.
3. A severe over-temperature condition has occurred. Repair or replace heater.
4. Turn on the correct circuit breaker in the main panel.
5. Turn off power at circuit breaker. Check supply wire continuity and proper
connection to heater wires.
6. The entire heater, or any of its components may be checked for continuity to
determine the cause of any problems. Repair or replace the heater or thermo-
stat.
4. Wash grill with hot soapy water and dry immediately.
5. While holding fan (to avoid damage or bending), use a hair dryer
or vacuum on blow cycle to blow debris through the top element
(do not touch element).
6. Vacuum fan area without touching the elements.
7. Do not lubricate motor.
8. Replace grill and secure with screws. Replace thermostat knob.
9. Turn thermostat to desired setting.
10. Turn power back on at the electrical panel board.