Specifications; Technical Data: Standard Design; Technical Data: Recessed Design; Disposal - Biral A 402 V2 Instrucciones De Instalación Y Funcionamiento

Bombas de circulación
Ocultar thumbs Ver también para A 402 V2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 100
80
Supply voltage:
Motor protection:
Degree of protection:
Winding class:
Ambient temperature:
Max. system pressure:
Noise
Leakage current:
Media temperature:
Ambient temperature:
Media temperature:
Ambient temperature:
english

11. Specifications

1×230 V +6/-10%, 50 Hz
No external motor protection is necessary
IP 44
insulation class H
max. 40 °C
10/16 bar
sound pressure level under 55 dB(A)
The pump's power line filter causes a leakage current
to the ground wire of less than 3.5 mA during operation.

11.1 Technical data: Standard design

+15 °C bis 95 °C
Media temperature: +15 °C to 95 °C
If a build-up of condensation water appears
(media temperature lower than ambient temperature)
the recessed design must be used.
max. 40 °C
Ambient temperature
°C
15
20
25
30
35
max. 40

11.2 Technical data: Recessed design

Media temperature: +15 °C to 110 °C
If a build-up of condensation water appears
(media temperature lower than ambient temperature)
we recommend the cold water design with condensation-resistant paint.
max. 40 °C

12. Disposal

This product and its parts must be disposed of ecologically.
Media temperature
Min. °C
15
20
25
30
35
40
Max. °C
95
95
95
95
90
70

Publicidad

Tabla de contenido
loading

Tabla de contenido