Water Filter Data
System
Specification
and
Performance
Data
Sheet
Refrigerator
Water
Filter
Cartridge
Model
WF50
I Specifications
Service
Flow
Rate (Maximum)
.............................................
075 GPM (2.83 Wmin)
Rated
Service
Life WF50-NI300
(Maximum)
........................
300 gallons/
3335 liters
Rated
Service
Life WF50-Wl5OO
(Maximum)
.......................
500 gallons/
3892 liters
Maximum
Operating
Temperature
........................................
100 ° F/38 ° C
Minimum
Pressure
Requirement
..........................................
35 psi/138
kPa
Maximum
Operating
Pressure
..............................................
120 psi/827
kPa
General
Use
Conditions:
Read this Performance
Data Sheet
and compare
the capabilities
of this unit with your
actual
water
treatment
needs.
DO NOT use this product
where
water
is microbiologically
unsafe
or of unknown
quality
without
adequate
disinfection
before
or after the system.
System
certified
for cyst
reduction
may be used
on disinfected
water
that may contain
filterable
cysts.
The Amana ® Clean
'n Clear
TM
retractable
water
filtration
system
uses a WF50
replacement
cartridge
(see Amana ® contact
information
at the front of your
manual
to order).
Timely
replacement
of filter cartridge
is essential
for performance
satisfaction
from
this filtration
system.
Please
refer to the applicable
section
in this owner's
manual
for general
operation,
maintenance
requirements
and troubleshooting.
This systems has been tested according to ANSI/NSF 42 and 53 for reduction of the substances
listed
below. The concentration of the indicated substances in water entering the system was reduced to a
concentration
less than or equal to the permissible limit for water leaving the system, as specified in
ANSI/NSF 42 and 53.
Performance
Data*
Substance
Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent
Water
0.15 mg/L
0.15 mg/L
25000 count/mL
11.8 NTU
0.00063 mg/L
0.0097 mg/L
1.9 mg/L
286667 count/mL
291.6667 ug/L
458 MFL/mL
Effluent
Average
0.001 mg/L
0.002 mg/L
lcount/mL
0.12 NTU
0.00005 mg/L
0.0002 mg/L
0.09 mg/L
900 count/mL
45.45 ug/L
0.16 MFL/mL
Average
%
Reduction
99.33%
98.66%
99.99%
98.98%
92.06%
97.93%
95.26%
99.68%
84.42%
99.96%
Maximum
Effluent
0.001 mg/L
0.003 mg/L
3 count/mL
0.18 NTU
0.00005 mg/L
0.0006 mg/L
0.17 mg/L
2400 count/mL
100 ug/L
0.16 MFL/mL
Min. Required
Inlet
Reduction
pH
0.010 mg/L
6.5
0.010 mg/L
8.5
> 99.95%
NA
0.5 NTU
NA
0.00001 mg/L
NA
0.003 mg/L
NA
_>75%
NA
_>85%
NA
0.0017 mg/L
NA
99%
NA
*
Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
**
Particle size range classification
of test. Particles used were 0.5-1
microns.
California Certificate number01-1486
22