◙ The temperature of the evaporating unit is too low. This may be caused by an obstructed
fluid line or the incorrect operation of a capillary. The consequences may be very serious,
for example ice may form on evaporating unit, etc.
◙ The compressor is functioning on cycles which are too short. This may also be due to
incorrect functioning of control humidistat.
◙ Compressor is overheated: low gas charge makes for insufficient flow of vapours to cool
the compressor. This may cause the tripping of the internal thermal indicator of the
compressor.
◙ The compressor operates continuously, there is not enough refrigerant to obtain the desired
results, and since the specified temperatures are not reached, the equipment does not shut
down.
In any case, it is better not to wait until a leak appears, and for this reason, it is recommended to
inspect the equipment regularly.
METHODS FOR SEARCHING FOR A GAS LEAK:
There are various tools on the market used in order to detect leaks, although not all of them are
sufficiently sensitive to certain types of refrigerants. It is very important to choose an adequate
detector for the refrigerant used for this equipment and that the maintenance guidelines to be
followed.
You can also use soap bubbles (liquid detergent in a spray bottle) to detect leaks.
Other methods such as halogen lighters and additives may also be used to detect leaks.
THE R-407-C GAS:
The R-407-C is NOT AN INFLAMMALBE gas; it has no flash point, and so is not subjected to
the rules and regulations of the transportation of inflammable gases.
The R-407-C does not irritate the skin, eyes or mucous membranes and does not produce any side-
effects.
It has a very low level of toxicity for one or many repeated exposures; it does not cause cancer or
mutations.
The R-407-C is susceptible may cause freezing if it comes into contact with the skin, due to its
immediate evaporation.
As with all hydrocarbons, whether they are halogenated or not, the R-407-C gas may, although it
has a very low level of toxicity, cause anaesthetic or pre-anaesthetic conditions if inhaled deeply
and within a closed area.

19. WARRANTY AND GENERAL CONDITIONS

The manufacturer guarantees the quality of the equipment specified in the LETTER OF
WARRANTY which should accompany this technical manual for start-up and other procedures.
The manufacturer's warranty does not cover breakage or damage resulting from the following
circumstances:
− Inadequate use or installation.
− Failure to follow the cleaning and maintenance instructions.
− Inappropriate chemical conditions.
− Operations done by unqualified personnel.
− Damage caused by inadequate risks.
− Damage caused by natural disasters.