The magazine is designed to drive screws completely into work piece
only. Once screwgun is lifted, adjustments to screw must be made by
first removing magazine.
Rotating the Collated Attachment
This attachment has the ability to rotate without being taken off the
drywall screwgun. To rotate, grip the top portion with one hand, while
holding the drywall screwgun with the other then rotate. An audible
"click" indicates the magazine is in each of the available positions.
MAINTENANCE
WARNING: To reduce the risk of injury, turn unit off
and disconnect it from power source before installing and
removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
Cleaning
WARNING: Blow dirt and dust out of all air vents with clean, dry air
at least once a week. To minimize the risk of eye injury, always wear
ANSI Z87.1 approved eye protection when performing this.
WARNING: Never use solvents or other harsh chemicals for
cleaning the non-metallic parts of the tool. These chemicals may
weaken the plastic materials used in these parts. Use a cloth
dampened only with water and mild soap. Never let any liquid get
inside the tool; never immerse any part of the tool into a liquid.
For best performance regularly clean magazine by:
1. Remove advancing mechanism from collated magazine (see
Removing and Installing the Advancing Mechanism
instructions).
2. Remove shoe from advancing mechanism.
3. Remove return spring from magazine.
4. Submerge parts in soapy water for 10 minutes.
Page dimensions: 8.5 x 5.5
5. Remove and thoroughly rinse parts.
6. Allow parts to air dry.
7. Reassemble and continue use.
REMOVING AND INSTALLING THE ADVANCING MECHANISM
(FIG. 8)
CAUTION: The advancing mechanism is spring loaded. Two
hands must be used to remove the advancing mechanism. The
spring may eject from the mechanism.
To remove advancing mechanism:
1. Remove collated magazine attachment from screwdriver.
2. Slightly depress advancing mechanism (D) by pushing on the
shoe (E) with one hand.
3. Keeping pressure on the shoe (E) with the other hand depress
service button (F).
4. Slowly release pressure from the shoe (E) until the advancing
mechanism is out of the collated magazine.
6