5.0 PARAMETER

5.1 ENTER SETTING MODE

Turn off the power of the scale and then turn the power on again.
Press the [Change/lb/kg] key during self-checking, display shows "Bee0", indicating
the scale has entered the setting mode, press the [Hold] or [Change/lb/kg] key to
shift the parameter items. Use [Zero] key confirm and escape from setting the
current item.

5.2 PARAMETER SETTING TABLE

FUNCTION
bEE
Hod
Stb
Aut
CHt
YES
© Adam Equipment Company 2013
DESCRIPTION
Sets buzzer
0: Disable
1: Enable
Sets hold function
0: Disable
1: Enable
Sets zero function
STb0: zeroing allowed when unstable
STb1: zeroing not allowed when unstable
Sets auto backlight: (Only applies when the scale has
an LCD display)
AUT0: manual
AUT1:auto
Sets units
0: lb
1: kg
Sets save:
0: not saved
1: save
12
DEFAULT
700660189RevD1-Jul13
0
0
0
0
1
0