Switch the touch control back on using the ON/OFF button
and all displays will be indicate "0", the decimal points will
flash and the touch control will be ready for cooking. If a
cooking zone is in "hot" mode, "0" and "H" will be alterna-
tely displayed.
Control of multiple circuits
Hobs without double or triple circuit, see Fig. 2A
Hob with double zone. (Fig. 2B)
When a dual cooking zone is activated, the two circuits are
switched on at the same time. Activation of the external cir-
cuit is indicated by a pilot light (7) in the bottom right corner
of the display. If only the internal circuit is to be switched
on, the external circuit can be switched off using the dual
circuit button (4). Press the dual circuit button (4) again to
re-activate the external circuit and the corresponding pilot
light (7) will switch on.
Sound signal (buzzer)
The following activities are indicated by a buzzer during use:
· Normal button pressing by a short sound.
· Buttons kept pressed down for more than 10 sec. by a
long, intermittent sound.
Maintenance (Fig. 4)
By means of a scraper immediately remove any alluminium
foil bits, food spills, grease splashes, sugar marks and other
high sugarcontent food from the surface in order to avoid
damaging the hob.
Subsequently clean the surface with some towel and
appropriate product, rinse with water and dry by means of a
clean cloth. Under no circumstance should sponges or abra-
sive cloths be used; also avoid using aggressive chemical
detergents such as oven sprays and spot removers.
Installer's Instructions
Installation
These Instructions are for the qualified technician, as a gui-
de to installation, adjustment and maintenance, according
to the laws and standards in force. These operations must
always be carried out when the appliance has been discon-
nected from the electric system.
Positioning (Fig. 5)
1 Front view
2 Front side
The appliance can be fitted into a working area as illustrated
on the figure. Apply the seal supplied over the whole peri-
meter of the working area.
Electrical connection
Prior to carrying out the electrical connection, please ensure
that:
the plant charac- teristics are such as to follow what is
indicated on the matrix plate placed at the bottom of the
working area;
- that the plant is fitted with an efficient earth
connection, following the standards and law
provisions in force.
- The earth connection is compulsory in terms of
the law.
Should there be no cable and/or plug on the equipment, use
suitable absorption material for the working temperature as
well, as indicated on the matrix plate. Under no circumstan-
ce must the cable reach a temperature above 50°C of the
ambient temperature.