Remove / Clean the Grease Filter
Risk of Fire! The performance of the exhaust
hood is affected by greasy debris; the risk of
fire increases with the amount of deposits.
In order to avoid the risk of fire, be certain to
regularly clean the metal filter.
(see „filter cleaning display"). Clean the filter
in a 14 day cycle, maximum. To do so, first
remove the three titanium plates: 1 Press
the titanium plates forward with both hands
on the lower edge, 2 then push them
upwards so that the titanium plates loosen
from their catches and can be removed.
The titanium plates are held in place with
magnets. 3 Now hold the metal filter by the
grip holes with both hands and push forward.
The metal filter is held in place with
magnets.
The metal filter is best cleaned in a
dishwasher with gentle dishwasher
detergent. The manufacturer offers no
guarantee in the event of possible
discoloration through the use of aggressi-
ve cleaning products. Temperatures above
55 degrees should also be avoided. Attenti-
on: Please do not use any 3 phase cleaners
or clean the filter in a commercial
dishwasher. Cleaning with aggressive
products such as benzene, acetone,
trichloroethylene, et cetera will lead to the
destruction of the filter! Replace the metal
filter after cleaning, then replace the three
titanium plates in reverse order, as was
done during assembly.
Change the Active Carbon Filter
(Option:Only with Hood with Circulating Air
Operation, D-Version)
Active carbon filters bind to odors that are
contained in cooking vapors. As per usage,
the filter must be exchanged after 3-6
months of operation.
- Press the catch in the direction of the arrows
and let down the filter frame
- Change the active carbon filter
- Replace and secure the filter frame
Activated carbon filter (option)
For activated carbon filters fitted in GUT-
MANN extractor hoods (C Version), please
read the separate operating instructions
provided!