akkuteam VAS 5901A Instrucciones De Uso página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 79
Errors in test
Before the open circuit voltage test, nothing appears on the display
mode
After establishing the battery connection, not all display elements are activated
Cause:
Remedy:
Cause:
Remedy:
Startability not displayed
After the startability test, the charger changes over immediately to the alternator test
Cause:
Remedy:
Errors during
Charger switches off during charging
charging
Cause:
Remedy:
Safety cut-out
If the battery does not reach a predefined voltage level within a given period, the charger
switches off. Please refer to „Technical data" for the length of time it takes before the
safety cut-out trips.
What to do in the case of a safety cut-out:
1. Unplug the charger from the mains
2. Disconnect battery connection
3. Determine cause of trip
4. Rectify fault and restart charging if necessary
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Battery is flat/in deep discharge
Charge a deep-discharge battery
Charger leads not connected to correct poles
Connect battery poles correctly
Very good battery and/or very high ambient temperature
System in very good condition. No remedial action necessary.
High ambient temperature. Charger overheating.
Allow charger to cool down. Charging will recommence automatically once
the charger has cooled sufficiently
These symbols are displayed alternately
Battery too large
Restart charging
Active accessories using too much power
Switch off accessories and restart charging
Faulty battery (e.g. cell short circuit, smell of gas, differing cell temperatu-
res, housing deforming, different liquid levels or liquid leaking, etc.)
Have battery checked. On no account allow charging to continue
Selector switch incorrectly set
Correct selector switch setting and restart charging
Incorrect charger type for this application
Have battery and charger checked and synchronised
6

Publicidad

Tabla de contenido
loading

Tabla de contenido