S8910U3000
REFERENCIA CRUZADA
DE LOS TERMINALES
S8910U
HS780
GND(BURNER)
6
TR (GND CLIP)
24V (GND)
GND
VALVE (GND)
—
24V
TH
VALVE
VALVE
L2
L2
L1
L1
HSI
IGN
HSI
IGN
SENSE
RS
CONTROL
DE GAS
COMBINADO
1
1
SUMINISTRO DE ENERGÍA. PROPORCIONE LOS MEDIOS DE DESCONEXIÓN Y DE PROTECCIÓN CONTRA SOBRECARGAS, SEGÚN SE REQUIERA.
CONTROLE QUE L1 Y L2 NO ESTÉN INVERTIDOS.
2
UBICACIÓN ALTERNATIVA DEL CONTROLADOR DE LÍMITES.
3
LA VARILLA DE DETECCIÓN ESTARÁ PRESENTE SI SE TRATA DEL MODELO HS780 CON DETECCIÓN REMOTA. CONSULTE LA TABLA 2.
4
CUANDO EL HS780 SEA UN MODELO CON DETECCIÓN REMOTA, RETIRE LA CONEXIÓN RÁPIDA DE PUENTE DEL MÓDULO S8910U.
CORTE EL CONDUCTOR EN LA PLACA DEL CIRCUITO Y DESÉCHELO. CONECTE EL CABLE CONDUCTOR DE LA VARILLA DE LLAMA A SENSE.
CONSULTE LA TABLA 2.
5
CORTE LA CONEXIÓN RÁPIDA DE 1/4 IN (4.7 MM) DEL CONDUCTOR Y REEMPLÁCELA CON LA CONEXIÓN RÁPIDA DE 3/16 IN (6.3 MM) (SUMINISTRADA).
6
UTILICE EL CABLE ADAPTADOR A TIERRA VERDE (SUMINISTRADO) PARA CONECTAR EL TERMINAL GND (BURNER)
DEL MÓDULO S8910U A LA CONEXIÓN A TIERRA DEL CHASIS.
Fig. 3. Conexión típica cuando el módulo S8910U reemplaza el modelo HS780 de Robertshaw.
34-00008EFS—01
CONTROL DEL ENCENDEDOR POR SUPERFICIE CALIENTE S8910U
S8910U Hot Surface Ignition
WARNING
Input Voltages = 120 & 24 VAC, 60 Hz
HSI = 120V, 5A max.
Valve = 24V, 2A max.
Explosion Hazard. Can cause
Total 24V Load = 0.4 + valve load
serious injury or death.
U.S. Patent 8,085,521
Disconnect power before ser-
Prepurge Time = 32 Sec.
vicing. This device can mal-
Igniter Warm Up Time = See Inst. Sh. 34-00008
function if it gets wet. Never
Ignition Trial Time - See Selection Tab
try to use a device that has
Number of Trials - See Selection Tab
been wet -- replace it.
Between Trial Time - 96 Sec.
6
CONEXIÓN A TIERRA
DEL QUEMADOR
MV
MV
TERMOSTATO O
CONTROLADOR
Golden Valley, MN 55422
Assembled in Mexico
Selection Tab
LED States
ON
Trial count
Control Status
OFF
= 1 try (default)
Device damaged- Red
ON
Trial count
replace control
OFF
= 3 tries
Ignition lockout
Trial for ign. period
ON
Normal operation Green Steady
OFF
= 4 seconds (default)
Weak flame signal Green Blink
ON
Trial for ign. period
See Instruction Sheet 34-00008
OFF
= 7 seconds
for additional states
1
2
3
4
120 VAC
120 VAC
See
NOTE: ALWAYS apply
NEUTRAL
HOT
LED
this control as instructed
States
in Instruction Sheet
34-00008
SYSTEM SETUP
5
CONTROLADOR
DE LÍMITES
2
12
Color Pattern
Steady
Red
Blink
®
C
US
AUTO
IGNITION
SYSTEMS
ANSI Z21.20
32304204-001 Rev. A
See
Instructions
for
SENSOR
Single/Dual
Rod
DE LLAMA
Applications
4
4 4
4
ENCENDEDOR POR
SUPERFICIE CALIENTE
L1
(CON CORRIENTE)
L2
1
3
MS8529