Controls and indicators
Figure 3
1.
Main motor Start/Stop switch
You can start/stop the main motor with this switch.
2.
Second motor Start/Stop switch
You can start/stop the second motor with this switch.
3.
Vacuum gauge
4.
Manual filter shaker lever
Inspections before starting
Figure 5
1.
Inlet
Before starting, check that:
■
The filters are installed;
■
The closing band is properly tightened;
■
The vacuum hose and tools have been correctly fitted
into the inlet (1);
■
The float system (11, Fig. 1) is properly installed inside
the liquid container (version L);
■
The Longopac
bag (2, Fig. 1) is installed (version GU).
®
WARNING!
Lock the caster brakes before starting the vacuum
cleaner (2).
WARNING!
Do not use the device if the filters are faulty.
Starting and stopping the vacuum cleaner
Figure 3
■
Toggle the switch (1) to the "ON" position to start the first
motor.
■
Toggle the switch (2) to the "ON" position to start the
second motor.
■
Toggle the switch (1) to the "OFF" position to stop the
first motor.
■
Toggle the switch (2) to the "OFF" position to stop the
second motor.
Liquid vacuuming stop
■
When the container is full, the float system (11, Fig. 1)
blocks the airflow; the vacuum units remain on.
■
Do not leave the vacuum units on after the float system
has tripped, to avoid unnecessary overloading of the
motors; turn the vacuum units off by turning the switches
(1 and 2) to "OFF" position.
11/2017
Operation
Vacuum gauge (2): green zone (3), red zone (1)
When using the vacuum cleaner, check the flow control:
■
when the vacuum cleaner is operating, the pointer of
the vacuum gauge must remain in the green zone (3)
to ensure that the speed of the intake air does not drop
below the safety value of 20 m/sec;
■
If the pointer is in the red zone (1) it means that the
speed of the air in the vacuum hose is less than 20 m/s,
and that the vacuum cleaner is not operating in optimal
conditions. Shake or replace the filter.
■
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
WARNING!
When the vacuum cleaner is operating, always check
that the vacuum gauge pointer remains in the green
zone (3).
Consult the "Troubleshooting" chapter if faults occur.
WARNING!
The air speed in the suction tube must not be less
than 20 m/s.
Condition indicated by the vacuum gauge pointer in
the green zone (3).
WARNING!
All vacuum cleaners can be used only with hoses
whose diameters comply with the specifications in the
"Technical Data" table.
WARNING!
Consult the "Troubleshooting" chapter if faults occur.
9
VHS 120 N1, N6
Figure 7
US
C449