_MS660.book Seite 84 Montag, 2. August 2010 8:03 20
MagicSafe MS660
Programming MagicSafe
Function 10 (Locking the central locking during self-activation)
This determines whether the vehicle should be locked or not after self-
activation of the alarm system. This function can only be used when
function 7 is programmed to "On".
Function 11 (Locking/unlocking with ignition)
When this function is activated, you can lock the vehicle when the ignition is
switched on by pressing the "Lock" button. In this case, the alarm system is
not activated.
The central locking unlocks the vehicle automatically when the ignition is
switched off.
Alternatively, the vehicle can be unlocked any time by pressing the "Unlock"
button.
Function 12 (Alarm detection for additional sensors)
MagicSafe features an additional alarm output (grey/white cable). This func-
tion allows you to determine whether this sensor alone can trigger the alarms
or whether it is only triggered in combination with the ultrasonic sensors.
Function 13 (Additional relay function)
This function is factory-set for use as a starter circuit breaker. This is already
active in "Standby" mode, not just in the event of an alarm.
This function can only be used when function 5 is programmed to "On".
If function 13 is programmed to "Alarm output", then this relay can, in the
event of an alarm, activate an additional warning device (e. g. a pager) or a
further siren or horn. In this case, the starter circuit breaker is not activated.
The siren or horn option can be determined by function 9.
Function 15 (Bonnet contact input)
This allows you to determine how the bonnet contact switch is connected.
The system is factory-set to a closed switch when the bonnet is open (voltage
0 volts). Should the switch used be open when the bonnet is open (voltage
12 volts), function 15 must be programmed to "Switch opened when bonnet
is open".
84