Problem
Encountered
@
@
Uneven mowing
results
@
@
Unit operates during
Inactive Time.
@
@
@
Unit operates during
rain
@
Cut wire indicator is
flashing on Power
Box
@
@
The poor connection
@
indicator is flashing
on Power Box
@
9.4.1.
Description of No-Depart Codes
Code
None. Automatic departure is working properly
8 8
Mower's battery is not yet in the required state for automatic
8 9
departure
Inactive Time is activated. No automatic departure during
8 A
Inactive Time
Mowing cycle is completed. Waiting for the next scheduled
8 E
operation
Humid conditions or rain were detected during last 30 minutes.
8 B
The mower is switched off
8 C
User response (interaction) is required in order to continue
8 F
current operation
Multiple consecutive mowing operations were shorter than
expected. Usually accompanied by U018 ("Operation time is
8 G
shorter than expected")
One-Time setup is running
8 R
Automatic operation is disabled by menu P021 (see Section 6.4.2)
9 9
Probable Cause/Event
The time between operations is too long
because of long inactive time windows.
Grass is growing very fast.
The shape of the lawn is complicated (Narrow
Passages, obstacle and islands).
The set area is smaller than the actual lawn size.
Wrong clock time is set in the mower.
Rain Sensor is disabled or its sensitivity is set
too low.
The Islands feature is set to on. In this case the
unit is searching for the base by moving around
the lawn. This special search method takes
more time, and may create an impression that
the unit is still mowing, while in fact it is already
searching for the Base Station.
The Extension Cable is disconnected or
damaged between Power Box and the Base
Station.
Perimeter Wire is cut.
Poor connections
Twisted cables or a screw terminal which is
insulated with insulation tape is not a
satisfactory splice.
Soil moisture causes the conductors to oxidize.
Description
Corrective Actions
Minimize the Inactive Time windows to allow the unit to
@
complete the Mowing Cycle faster and to achieve even
mowing results.
If it is during a fast growing season – change the Mowing
@
Frequency (refer to Section 6.4.2 – P001).
In a complicated lawn more time is required for the lawn to
@
achieve better mowing results.
Increase the mowing hours percentage (refer to Section
@
4.3.2.1).
Increase the zone area (refer to Section 4.3.3 Edit an
@
existing Zone).
Verify that the time on the unit is set correctly.
@
Set the time (refer to Section 4.4.4).
@
Reset the Inactive Time (refer to Section 4.3.1).
@
Enable the Rain Sensor and adjust its sensitivity if required
@
(refer to Section 6.4.2 – P007/p008)
No special action is required. For more information about
@
the Islands On/Off feature refer to Section 6.4.2 – P002),
Confirm the Extension Cable is plugged in and wire leads
@
are firmly attached.
Walk along Perimeter Wire.
@
Look for cuts or breaks in the wire.
@
Repair with the unit wire splice connectors.
@
Check and repair all loose, poor, or corroded connections.
@
Use the connectors supplied in the box. They are
@
waterproof and give a reliable electrical connection.
Corrective Action
None. Wait for the end of current charging cycle
None. Wait for the end of current charging cycle. May take
longer than usual
None. Validate Inactive Time settings (see Section 6.4.1)
None
• None. If the rain has stopped, wait at least for another 30
minutes.
• If it there was no any raining at all, consider adjusting rain
sensor's sensitivity (see P008 in Section 6.4.2) or call the unit
Hotline
Switch on the Safety Switch
Acknowledge the error message
• Inspect mower's blade and drive wheels.
• Battery run-time may be too short.
One-Time setup should be completed before the automatic
operation can start
Enable automatic operation through menu p021