3-4 Error count
3-5 RX type
PCM12 35A V2.68
3-6 RX reset
L
3-7 Send data
L
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions - MULTImate – V1.42
3-4 Go back
...to RX M-PCM
3-4 RF error
0
3-4 Volt. err.
0
3-4 Sign. err.
0
3-4 Clear errcnt
L
3-4 Low voltage
4.3 Volt
Display of recorded RF errors*
Display of recorded low-voltage errors*
Display of recorded signal errors*
* The counter can only be read out if the errors were
stored in the receiver before it was switched off: this is
accomplished by briefly pressing the SET button on the
receiver when errors are indicated.
Erase error counter completely:
Selecting the voltage threshold for low voltage errors
Can be selected from 3.0 Volt to 6.9 Volt
Alter value using and
with
Display of connected receiver type
Description (PCM12)
Frequency band (35 MHz A-band)
Software version (V2.68)
If you wish to reset the receiver to the factory default
settings:
Caution:
The previously set values and / or data must be sent
to the receiver via this menu point, otherwise they
will not take effect.
The only exception from this is the menu point:
"3-6 RX reset"
• To send the selected data: