5.
M
4: RX M-LINK
ENU
This menu point is used when you wish to use the MULTImate to set up a MULTIPLEX RX-DR / DR pro M-LINK
receiver (does not work with MULTIPLEX RX-light receivers).
•
Use the supplied data lead to connect the receiver (socket marked "B/D") to the PC and Data port on the end
of the MULTImate.
Aktion & Display
4 RX M-Link
4-1 RX Name
7934BE654FFB
4-2 Failsafe
4-3 Hold length
0.5 sec
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions - MULTImate – V1.42
4
Go back
...to main nenu
4-1 Go back
...to RX M-Link
4-1 v-----------
7934BE654FFB
4-2 Go back
...to RX M-Link
4-2 Servo 1
L
< FS off >
(...)
(...)
4-2 Servo 16
L
< FS off >
4-2 FS length
15.0 sec
Explanation
Main menu display „4 RX M-LINK"
Changing the receiver name
• Use
or
to position the v over the character to be
changed.
• Press and use
or
confirms the selection,
character to be changed.
Selecting the fail-safe setting for servo 1, ... ,16
•
Select the servo 1, ..., 16 using
•
Fail-safe for the selected servo on / off:
•
Change the fail-safe setting:
and
or
, confirm with
Note: after receiver reset all servos are set to:
Fail-safe "off"
Selecting the fail-safe period (max. fail-safe time
after the Hold time has elapsed)
• Available range 0.0 sec. to 32.0 sec.
• Change value with and
confirm selected value with
Selecting the Hold period - applies to all servos
• Available range 0.0 sec. to 0.76 sec.
• Change value with and
confirm the set value with
to select the new character.
moves on to the next
or
or
,
or
,