> Press
menu up/down buttons to toggle between SPA MODE on and off;
> Press
menu/setting select once your preferred SPA MODE is displayed;
> This will then take you back to the first setting menu;
> If the EcoSalt2 is left untouched for ~ 30 seconds, or the
pushed, the display reverts to the HOME screen.
ACTIVATING SPA MODE AND COVER MODE SIMULTANEOUSLY
Should it be necessary to run SPA MODE and COVER MODE simultaneously, the cell duty cycle is only
reduced by 80% That is, the cell duty cycle isn't reduced by 80%, followed by a further 80%. The HOME
screen display will toggle between showing COVER and SPA.
ACTIVATING WINTER MODE
A pool's exposure to UV contributes significantly to the pool's total chlorine demand. Ie the amount of
chlorine the pool uses. Bather load is also a significant contributor to the pool's total chlorine demand. In
winter, the pool's chlorine demand is typically far less. Unless otherwise altered, if the cell is producing
chlorine, it is producing at 100% current (output). WINTER MODE reduces the cell's current (output) to 85%.
For example:
• If the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 100%, the WINTER MODE is
off: the EcoSalt2 cell duty cycle is 10 hours. The cell current will be operating at 100% capacity;
• If the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 100%, but the WINTER
MODE is on: while the EcoSalt2 cell duty cycle is still 10 hours, the cell current will only be operating at
85% capacity.
To turn on WINTER MODE:
> From the HOME screen, press
3. SPA
OFF
menu/setting cancel (go back) button is
70% – 09:35 AM
CHLORINE OUTPUT
menu/setting select.