Temperature Compensation - CTEK MULTI XS 25000 Manual Del Usuario

Ocultar thumbs Ver también para MULTI XS 25000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Recond (Lamp 5) (only on MULTI XS 25000 and MULTI XT 14000)
This mode is used to recover deeply discharged flooded batteries. Recondition of deep discharged batteries. The voltage
increases with reduced current for a limited time period. The higher voltage starts some gassing and mixing of the acid, which is 
beneficial for both battery capacity and expected life. Note that the battery could emit explosive gas during Recond. Recond is
performed between Analysis and Maintenance.
INDICATORS
Lamp
Description
0
Fault mode, the charging is discontinued. For fault causes, see below.
1
Start mode
2
Bulk charging
3
Absorption charging
4
Maintenance charging
5
Supply (Only on MULTI XS 5000 and MULTI XT 14000)
6
Recond reconditioning of completely discharged batteries. (Only on MULTI XS 5000 and MULTI XT 14000)
A
Charging without temperature compensation.
B
Mains voltage connected
C
Normal (Only on MULTI XS 5000 and MULTI XT 14000)
D
Supply (Only on MULTI XS 5000 and MULTI XT 14000)
E
Recond (Only on MULTI XS 5000 and MULTI XT 14000)
Fault mode
The charger goes to fault mode in the following situations:
The battery is connected with poles reversed to the charger's terminals.
  T he charger's analysis function has interrupted charging.
The terminals on the charger are short-circuited after charging has started.
The charger has been in start mode for more than 4 hours.

TEMPERATURE COMPENSATION

MULTI XS 5000, XS 5000, MULTI XT 14000 and XT 14000 have a sensor cable placed together with the battery cables. The 
units will automatically adjust the charging voltage if the temperature deviates from +5°C. A high temperature lowers the voltage 
and freezing conditions is handled by higher voltage.
The temperature is best measured on or very close to the battery. Therefore always place the sensor as close to the battery as 
possible when charging. The sensor cable could be prolonged or cut to length with the same functionality. A short-circuited or 
disconnected sensor is indicated by lamp A. The charging voltage is then adjusted to the +5°C condition.
4  •  GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xs 25000Multi xt 14000Xt 14000

Tabla de contenido