IO-Link Data Dictionary
21.10.01.00065/02
208
0x00D0
Permissible leakage rate
Production Setup - Profile P3
220
0x00DC
Air saving function
221
0x00DD
Disable continuous suction
222
0x00DE
Setpoint H1
Hysteresis h1
223
0x00DF
224
0x00E0
Setpoint H2
225
0x00E1
Hysteresis h2
226
0x00E2
Duration automatic blow
Permissible evacuation time
227
0x00E3
228
0x00E4
Permissible leakage rate
Commands
2
0x0002
System command
120
0x0078 CAL
Calibrate vacuum sensor
123
0x007B rES
Restore to factory defaults
Observation
Process Data In Copy
40
0x0028
41
0x0029
Process Data Out Copy
System vacuum
64
0x0040
66
0x0042
Supply voltage
65
0x0041
Input pressure
J. Schmalz GmbH
2 bytes
1 - 999
rw
1 byte
0 - 2
rw
1 byte
0 - 1
rw
2 bytes
998 >= H1 >= (H2+h1)
rw
2 bytes
(H1-H2 >= h1 > 10
rw
2 bytes
(H1-h1 >= H2 >= (h2+2)
rw
2 bytes
(H2-2) >= h2 >= 10
rw
2 bytes
100 - 9999
rw
2 bytes
0, 10 - 9999
rw
2 bytes
1 - 999
rw
1 byte
wo
1 byte
1
wo
1 byte
1
wo
1 byte (V1.0)
ro
4 bytes (V1.1)
1 byte (V1.0)
ro
2 bytes (V1.1)
2 bytes
ro
2 bytes
ro
2 bytes
0 - 99
rw
5 of 11
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
250
Profile P-3
1
(selected by PD Out 0 - Profile-Set = 3)
0
750
150
550
10
200
2000
250
0x05 (dec 5): Force upload of parameter data into the master
0x82 (dec 130): Restore device parameters to factory defaults
0xA4 (dec 164): Clear diagnostic buffer
0xA5 (dec 165): Calibrate vacuum sensor
1 = Calibrate vacuum sensor
(can also be executed by switching PD Out 0 Bits 2 and 3 simultaneously
from 0 to 1)
1 = Restore to factory defaults
Copy of currently active process data input
Copy of currently active process data output
Current vacuum level (unit: 1 mbar)
Supply voltage as measured by the device (unit: 0.1 Volt)
0
Pressure value from external pressure sensor (unit: 0.1 bar)
SCPSi series
29.08.2014
SCPSi Data Dictionary