Astralpool 37059 Manual De Instalación página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3
10 mn
Filtering
and
robot
working for 10 minutes, your immersion
detector is monitoring (indicator light off) and
must not go off.
5
The siren must sound within a maximum of
12 seconds after the fall. Stop the siren
using the magnet.
Wait for the automatic rearming (indicator light off). This may take about ten minutes.
You must always perform additional fall tests at different locations in the pool (including
steps) according to the procedure described above.
After each fall, you must wait for the automatic reactivation of your immersion detector
before performing another fall. Depending on wind and pool disturbance conditions, this
reactivation may take about ten minutes.
Warning: when your device switches out of TEST mode (specific tune), the siren
of your immersion detector will sound at full volume. The TEST mode can be
reactivated for another 30 minutes: to do this, please refer to item 4.5.
If one of these tests fails:
I
Look up item 5.
Contact your retailer for advice.
I
I
Check with the AstralPool After Sales Service at +34.93.713.63.44.
Send a letter to the AstralPool technical department, clearly describing your problem, and leaving
I
your details at the following address:
cleaner
AstralPool SAU
Avda Francesc Macia, 38 Planta 18
08208 Sabadell – Spain
10
4
With the filtering system and robot cleaner
working, drop the 6 kg weight from the
point furthest away from your immersion
detector.