The siren must sound within a maximum of
12 seconds after the fall. Stop the siren
using the magnet.
Wait for the automatic rearming (indicator light off). This may take about ten minutes.
You must always perform additional fall tests at different locations in the pool (including
steps) according to the procedure described above.
After each fall, you must wait for the automatic reactivation of your immersion detector
before performing another fall. Depending on wind and pool disturbance conditions, this
reactivation may take about ten minutes.
If one of these tests fails:
I
Look up item 5.
Contact your retailer for advice.
I
I
Check with the AstralPool After Sales Service at +34.93.713.63.44.
Send a letter to the AstralPool technical department, clearly describing your problem, and leaving
I
your details at the following address:
You have successfully completed all your validation tests. You can now carry out the last operations
below:
7
x4 x4
Warning, it is essential that the
4 caps are put in place.
Regularly check the water level in your pool, especially when the weather is very hot,
or rainy, or if it has been windy for several days. The immersion depth must imperatively be
15 centimeters plus or minus 3 centimeters. If the immersion depth is not respected your
immersion detector will not work properly.
AstralPool SAU
Avda Francesc Macia, 38 Planta 18
08208 Sabadell – Spain
8
Fill out the test validation sheet and send it
to AstralPool.