Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62

ERROR CODES

CL
Machine is in blade clean mode.
Safety hoods are not fixed properly or not present.
Push both start buttons and wait until timer reaches 0.
STA
Emergency button is not unlocked
E1
Safety hoods are not fixed properly or not present.
E2
Dividing head is in wrong position.
E3
The chamber height is too low compared to the dough weight
The pressing time is too long.
There is an object in front of the blue sensor on the right side of the head.
Motor is overloaded : thermal safety has jumped off
E4
Moulding ring is not present.
E5
Start buttons not pushed long enough.
Electric phases are wrong.
The blue sensor on the right side of the distributor head is defective.
The connection of the blue sensor to the circuit board is wrong.
The cable that runs to the blue sensor is interrupted.
The room height switch is broken or not activated
E6
ENG
11

Publicidad

Tabla de contenido
loading

Tabla de contenido