The OPEN input mode is selected
On: OPEN input with WATCH function. To be used for the connection of timed
CLOC
opening/closing. (CLOSED contact - open gate. OPEN contact - normal opera-
tion).
Off: OPEN input with OPEN function.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
During the TCA phase, the PP and PED controls are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled.
ENC
On: enabled Encoder, braking activated.
Off: disabled Encoder, braking deactivated
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
The second radio channel is enabled or disabled on terminal AUX.
On: AUX output, preset as second radio channel.
SERL, TST1 and TST2 logics should be preset on OFF.
2CH
Off: AUX output can be preset as SCA, or by SERL, TST1 and TST2 logics(the
programming of a radio control in the RADIO 2CH menu allows for the pedestrian
passage opening).
The service light function is enabled or disabled on AUX output.
On: At each operation the contact is closed for the time preset with TLS
SERL
parameter. TST1, TST2 and 2CH logics should be preset on OFF.
For the light control, use an auxiliary relay.
Off: AUX output can be preset as SCA, or by 2CH, TST1 and TST2 logics.
Check of photocells on PHOT O input is enabled or disabled.
TST1
On: check is enabled. If check is not successful, no operation is enabled.
Off: AUX output can be preset as SCA, or by 2CH, SERL and TST2 logics.
Check of photocells on PHOT C input is enabled or disabled.
TST2
On: check is enabled. If check is not successful, no operation is enabled.
Off: AUX output can be preset as SCA, or by 2CH, SERL and TST1 logics.
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the
photocell is released, the motor restarts in the opening phase.
PHTC
In closing phase: the contact opening causes the motor stop. When the photocell
is released, the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the
immediate reversion of the operation direction (open).
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
16
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)