Aventics ED12 Instrucciones De Servicio página 50

Ocultar thumbs Ver también para ED12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

50
AVENTICS | ED12 | R414002587–BDL–001–AB
Assembling the ED12
3
5
2
2
1
00125289
2
1
3
00125290
Table 9:
4
Integrated X2M socket, M12, female, 5-pin
Pin 1
Pin 2
1
Pin 3
00125283
Pin 4
Pin 5
The X1S pin 3 and X2M pin 3 contacts are connected internally
Table 10:
Rectangular X1S plug, form A
Pin 1
Pin 2
Pin
Table 11:
Rectangular X2A plug, form A
Pin 1
Pin 2
Pin 3
Pin
The X1S pin 1 and X2A pin 1 contacts are connected internally.
Make sure before connecting the plug that all seals and
connections are included and not damaged.
Only use tested plugs and cables.
Protect the supply voltage with an external M 2.5 A fuse.
ED12 with integrated X2M socket, M12
Pressure reached switch output
Set point (+): current 0/4 to 20 mA or voltage 0 to 10 V
DC
0 V
Actual value (+): current 0/4 to 20 mA or voltage 0 to
10 V DC or 10 V DC constant
Functional grounding (FE)
ED12 with two rectangular DIN EN 175301-803 plugs
0 V
24 V DC
Functional grounding (FE)
ED12 with two rectangular DIN EN 175301-803 plugs
0 V
Set point (+): current 0/4 to 20 mA or voltage 0 to 10 V
DC
Actual value (+): current 0/4 to 20 mA or voltage 0 to
10 V DC or 10 V DC constant
Functional grounding (FE)

Publicidad

Tabla de contenido
loading