15. Open the front door, remove the grease filter (see
paragraph "Maintenance - Front Door" and
"Maintenance - Grease filter") and secure hood with 1
screw on bottom.
16. Ductless (recirculating) version:
Install the deflector on top of the hood.
Ducting version ONLY:
Install the transition on top of the hood with 2 screws.
Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
17.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
On top of the hood on the right side is found the Junction
box, remove the knockout and the Junction box cover
and install the conduit connector (cULus listed) in
junction box cover.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
18. For Ductless (recirculating) installations
Install one charcoal filter.
19. Install metal filter and close the front door ((see
paragraph "Maintenance - Front Door" and
"Maintenance - Grease filter").
20. Check all light bulbs to make sure they are secure in
their sockets.
Turn power (On) in service panel.
Controls start flashing for about 15 secs to indicate they
are calibrating themselves, wait until flashing stops (only
Motor touch sensor key OFF (stand by) is ON - see
also paragraph "Controls").
Calibration is repeated any time the hoos is
disconnected intentionally or not from power supply (i.e.:
Black out).
Then check lights and blower operation.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wiring is correct.
9