Input Wiring - Vimar RS09 Manual Para El Conexionado Y El Uso

Tarjeta con trimmer 230/120 vac para cancelas correderas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
RS09/RS09.120
3.1- Wiring for power line, flashing light and electric motor:
3.2- Wiring for 24V outputs:
Second radio channel or photo-test output
Output for viewing gate movement
Terminal
Description
number
1-2-3
Power supply line
4-5
Output for flashing light
6-7-8
Output for powering the electric motor
9-11
Second radio channel or photo-test output Second radio channel or photo-test output (can be selected with dip switch 1-3 and 9 =
10-11
Gate movement warning output
11-12
24 Vdc output
The sum of the absorptions of the 2CAN, AUX and -VA outputs must not exceed 500 mA

3.3- Input wiring:

The control panel is supplied with non-jumpered normally closed safety inputs (STOP, FOTO, STPA), add a jumper between the common (COM) and
input you do not intend to use
230/120 Vac
ELA3
2CAN AUX +24V GND
Function
230/120 Vac power line (1 = phase / 2 = ground wire / 3 = neutral)
Output for flashing light (230/120 Vac max 60 Watt)
Output for powering the electric motor (6 = common / 7 = opens / 8 = closes) the
capacitor is connected in terminal 7 and 8 in parallel with the electric motor
GND / 11= +24 Vdc max 120 mA)
Gate movement warning output (10 = GND / 11 = +24 Vdc max 120 mA)
24 Vdc output to power photocells and accessories (11 = GND / 12 = +24 Vdc 300mA)
M
Fig. 4
-
-
+
-
24Vdc output to power photocells and accessories
EN
M
Fig.3
M
Fig. 5
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rs09.120Tvox rs09Tvox rs09.120

Tabla de contenido