Cebora SOUND MIG MIG 3540/T STAR PULSE Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
LED AQ SYNERGIC MIG.
Shows that the selected process is synergic MIG.
LED AR CONVENTIONAL MIG.
Shows that the selected process is conventional MIG.
LED AS TIG.
Shows that the selected process is TIG.
LED AT MMA.
Shows that the selected process is MMA.
Selection key AU.
Each brief pressure selects 2 stages mode (MANUAL)
and the 4 stages mode (AUTOMATIC), the selection is
shown on the display AL.
In the 2 stages mode the machine begins welding when
the welding torch trigger is pressed, and stops when
released.
In the 4 stages mode to begin welding press and release
the welding torch trigger; to interrupt, you must press and
release it again.
Selection key AV. (JOB)
Saving and restoring of the stored processes.
To save a working condition (JOB), just hold down for at
least 3 seconds the key AV, the LED AZ glows, on the
display AL the abbreviation STO flashes and on display
AM the number of the first available position flashes.
Knob AN is used to select the saving position; press
again key AV until a sound will confirm that it has been
saved and the selected number stops flashing.
To restore the saved number just briefly press key AV and
restore the number by means of knob AN. Up to 99 pairs
od current/voltage values may be saved.
To delete a saved number, press for at least 3 seconds
key AV, turn knob AI until the display ALshows the abbre-
viation DEL and press the key againAV for 3 more sec-
onds.
A current/voltage parameter may be restored outside
saving for both using or changing it. To restore it press
for 3 seconds key AV, display by menas of knob AI the
number to be restored and show on display AL, with
knobANthe abbreviation rcL; now just press for at least 3
seconds key AV.
LED AZ JOB.
Shows that you are inside the saving menu of the saved
working points.
Selection key AY.
Gas Test .
When this jey is pressed gas stars flowing; to stop it press
the key again.
If the second press does not takes place the gas output
is interrupted after 30 seconds
Selection key AW.
Wire test.
Allows the wire feed with no current or voltage present.
When this key is held down, during the first 5 seconds the
wire advances at the speed of 1 meter per minute and
then the speed increases up to 8 meters per minute.
When this key is released the motor stops immediately.
5. SERVICE FUNCTIONS.
Press the key AE, and hold it down for at least 3 seconds
to enter the submenu. Turning the knob AI you select the
function, shown on the display ALand turning the knob
AN you select the type of operation or the value, shown
on the display AM. To return to the normal display, press
and release the key AE immediately.
5.1. MIG PROCESS.
1- H2O (Cooling unit, optional).
Turning the knob AN you select the type of operation:
OFF = shut off, ON C = always on, ON A = automatic
start-up.
When the automatic mode is selected the pump begins
working immediately at each welding start command and
stops 3 minutes after the welding is completed.
At each power source start-up a short pump test takes
places for15 seconds.
If an insufficient presssure is detected the machine goes
into warning mode and H2O flashes on display AM.
If th elow pressure condition persists for more than 30
seconds, the pump is disactivated and the machine goes
to error mode (ERR 75).
2- TRG.
Activated in MIG welding. Choice between 2- or 4-
stages , 3 levels, the selection 2t and 4t with the selec-
tion key AU, without entering the service functions.
2t the machine begins welding when the welding torch
trigger is pressed, and stops when released. 4t to begin
welding press and release the welding torch trigger; to
interrupt, you must press and release it again. 3L this pro-
cedure is active in the synergic processes. Specially well
suited to weld aluminum.
3 currents are available that can be used in welding by
means of the welding torch start button. The current and
the slope values are set as follows:
SC starting current (Hot Start). With the possibility of
adjusting from 1 to 200% of the welding current, a value
adjusted using the knob AN.
Slo slope. Possibility of adjusting from 1 to 10 seconds.
Defines the connection time between the first current SC
with the welding current and the second current with the
third current CrC ( crater filler current), a value set by
means of knob AN.
CrC - «Crater filler» current. With the possibility of adjust-
ing from 1 to 200% of the welding current, a value adjust-
ed using the knob AN.
Welding starts at the welding torch button pressure, the
named pressure will be the starting pressure SC.
This current is kept as long as the welding torch button is
held down; when the welding torch trigger is released the
first current connects to the welding current, set by
means of
knob AI, and is kept as long as the welding
torch button is held down. When the welding torch trig-
15

Publicidad

Tabla de contenido
loading

Tabla de contenido