3.3.- Anomalies.
In the case of a breakdown or malfunction, check:
− Correct voltage of the machine.
− That the mains water and gas pressures are correct.
− The status of the fuses.
− The delimer must be regenerated periodically, following the manufacturer's instructions.
− If the door joint is dirty, steam will come out. Clean the door joint.
− If the drain is blocked, water is deposited in the cooking chamber. Clean by means of plug D
(Fig. 1).
− In the case of a breakdown, the electronic thermostat of the oven chamber 12 (Fig. 5) will
lock and the following message will appear on display 12 (Fig. 5) or on display 8 (Fig. 6):
0 Thermocouple cut.
1 NTC open.
2 0-270ºC selection potentiometer is faulty.
3 100ºC potentiometer is faulty.
− If the core probe temperature indicator 16 (Fig. 5) indicates 800 and a bell rings, this means
that that the core probe has been cut at some point.
− If the lower luminous button of the control panel 21 (Fig. 5), or 12 (Fig. 7) comes on and a
bell rings, the chamber burner ignition system is locked.
− If the luminous button 22 (Fig. 5) comes, the ignition system of the generator burner is faulty.
Failure modes of the electronic inverter T-083002:
1. One pulse of light in the red LED. Possible causes:
- PWM exit failure. (Motor reaches maximum velocity and control does not respond).
2. Two pulses of light in the red LED. Possible causes:
- CC-N=220V and GV-GV= only 5". (Ignition control blocked, flame not detected)).
3. Three pulses of light in the red LED. Possible causes:
-.The hall entry detects impulses below 100 R.P.M. (damaged motor)
4. Four pulses of red LED. Possible causes:
-. Motor does not reach maximum speed ±10% (5" sampling appears 2 or more times)
5 Five pulses of red LED. Possible causes:
-.Motor does not reach minimum speed ±10% (5" sampling appears 2 or more times)
6 Red LED constantly lit. Possible causes:
-.CC-N=220V and GV-GV not received after 5".(Ignition control damaged).
In all these case the repair service will resolve all these problems.
NOTE: When a repair is made, unblock the appliance by means of key 21 and 22 in HGV and
key 13 in HGC.
This appliance is only for professional use and
it should be used by qualified personnel
30