9
Day detection (panels irradiated)
10
Load output
6) The parameter BMS present will be set to 'Y'es internally when a
compatible BMS is detected, this setting can be used to revert the charger to
normal operation (i.e. without BMS) by setting it manually to 'N'o. Do not set
this parameter to 'Y'es when using a VE.Bus BMS connected to the remote
on-off input.
7) Load operation mode
Value
Description
0
Load output always off
1
Batterylife algorithm (default)
2
Conventional algorithm 1 (off<22.2V, on>26.2V)
3
Conventional algorithm 2 (off<23.6V, on>28.0V)
4
Load output always on
5
User defined algorithm 1 (off<20.0V, on>28.0V)
6
User defined algorithm 2 (off<20.0V<on<28.0V<off)
8) VE.Direct port RX pin mode
Value
Description
0
Remote on/off (default)
1
Load output configuration
2
Load output on/off
9) VE.Direct port TX pin mode
Value
Description
0
Normal VE.Direct communication (default)
1
Pulse every 0.01kWh
2
Light dimming control (pwm normal)
3
Light dimming control (pwm inverted)
4
Virtual load output
10) Backlight automatic turn-off has the following options: OFF=backlight
remains lit all the time, ON=the backlight will dim 60s after the last keypress,
AUTO=when charging the backlight is lit, otherwise it will dim.
11) Press SELECT: the text "" will blink, press SELECT again to reset
to original factory settings. The charger will re-boot. The history data will not
be affected (kWh counter, etc).
12) Press SELECT: the text "" will blink, press SELECT again to erase
the history data (kWh-counter, etc). Note that this takes a few seconds to
complete.
Note: any setting change performed with the pluggable LCD display or
via Bluetooth will override the rotary switch setting. Turning the rotary
switch will override prior settings made with the pluggable LCD display
or via Bluetooth.
Warning
Some battery manufacturers do recommend a constant current
equalization period, and others do not. Do not use constant current
equalization unless recommend by the battery supplier.