A binary LED code helps determining the position of the rotary switch.
After changing the position of the rotary switch, the LEDs will blink during 4
seconds as follows:
Switch
LED
position
Float
0
1
2
3
4
5
6
7
Thereafter, normal indication resumes, as described in the LEDs section.
3.7 Configuration of the controller with VictronConnect
Use VictronConnect to configure and monitor the charge controller.
VictronConnect is available for Android, iOS, Windows and Mac OS X.
VictronConnect is also available for download from the website
https://www.victronenergy.com/support-and-downloads/software
3.8 Automatic equalization
Automatic equalization is default set to 'OFF'. By using the configuration
tool VictronConnect or the pluggable LCD display this setting can be
configured with a number between 1 (every day) and 250 (once every 250
days). When automatic equalization is active, the absorption charge will be
followed by a voltage limited constant current period (see table in section
3.5). The current is limited to 8% of the bulk current for all VRLA (Gel or
AGM) batteries and some flooded batteries, and to 25% of the bulk current
for all tubular plate batteries and the user defined battery type. The bulk
current is the rated charger current unless a lower maximum current setting
has been chosen.
In case of all VRLA batteries and some flooded batteries (algorithm number
0, 1, 2 or 3) automatic equalization ends when the voltage limit maxV has
been reached, or after t = (absorption time)/8, whichever comes first.
For all tubular plate batteries and the user defined battery type automatic
equalization ends after t = (absorption time)/2.