1. INSTALL DUCTWORK AND ELECTRICAL WIRING
1.1 N
-D
I
ON
UCTED
NSTALLATION
One of the following non-duct kit ANKCP Series must be installed (sold separately):
• ANKCP4536 for CP45I362SB and CP45I369SB
• ANKCP4748 for CP47I482SB
1.2 D
I
UCTED
NSTALLATION
Either CP45I, CP47I or CP47E Series power packs may be ducted. For a CP47E Series power pack, either an exterior
blower or in-line blower must be used. The CP47E Series power pack must be installed with blower models ILB3, ILB6,
ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted (blowers sold separately.) Plan where
and how the ductwork will be installed.
If installing exterior or in-line blower, refer to instructions packed with blower and follow steps 1 up to 7, 11, 13,
15, 17 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If installing CP45I Series
power pack, use 8" round ductwork and if installing CP47I or CP47E Series power pack, use 10" round ductwork. Use
metal foil duct tape to seal duct joints.
1.3 A
I
LL
NSTALLATIONS
The minimum power pack distance above cooktop must not be less than 24''. A maximum of 30" above cooktop
is recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
Run 3-wire power supply cable to installation location. Its length should extend at least 4 feet below the bottom of the
custom hood.
ROOF CAP
WALL
CAP
24" TO 30"
HH0113A
ABOVE COOKING SURFACE
CP45I (
SINGLE INTERNAL BLOWER
CP47I (
DUAL INTERNAL BLOWER
T
YPICAL
(CP45I
AND
8" ROUND DUCT FOR CP45I OR
10" ROUND DUCT FOR CP47I
8" ROUND ELBOW FOR CP45I OR
10" ROUND ELBOW FOR CP47I
10" IN LINE
VERTICAL DAMPER FOR CP47I
8" ROUND ADAPTER & DAMPER
FOR CP45I OR
10" ROUND ADAPTER FOR CP47I
POWER PACK
)
OR
)
D
UCTWORK
EXTERIOR BLOWER
EXTERIOR
BLOWER
HH0115A
CP47E E
XTERIOR
CP47I S
ERIES POWER PACKS ONLY
• ANKCP4742 for CP47I422SB
• ANKCP4760 for CP47I602SB
(except ILB3, 8'' ROUND DUCT)
IN-LINE BLOWER
24" TO 30" ABOVE
COOKING SURFACE
HH0114A
CP47E
WITH
I
-
N
LINE
(
BLOWER LOCATION IS SHOWN FOR REFERENCE ONLY
10" ROUND DUCT
10" ROUND ELBOW
POWER PACK
24" TO 30"
ABOVE
COOKING SURFACE
B
T
D
LOWER
YPICAL
UCTWORK
- 5 -
)
10" ROUND DUCT
POWER PACK
M
ILB3, ILB6, ILB9
ODEL
B
T
D
LOWER
YPICAL
UCTWORK
ROOF CAP
WALL
CAP
ILB11
OR
)