17. INSTALL THE EXTERNAL BLOWER CONNECTIONS
Do not plug the two cords together.
To install the blower see instructions included with the blower.
Plug the 3-prong plug cord from rough-in plate to the 3-prong male
connector inside the power pack (A) and the 2-prong male connector
cord from rough-in plate to the 2-prong plug inside the power pack (B).
18. REINSTALL BOTTOM PANEL
Lift the bottom panel and engage the power pack metal tabs
in bottom panel slots, as shown in details A and B below.
A
HO0121
19. REINSTALL GREASE DRIP RAIL
A. Insert one end of grease rail in power
1
pack side (
) while lifting the other end
over the bottom panel edge (
B. Center the grease drip rail over the bottom
panel edge and flip it to snap in place.
WARNING
!
S
IDE VIEW
B
1
2
).
HD0292
(CP47E SERIES ONLY)
HE0078
Secure the bottom panel to the power pack using its screws
previously removed in step 7.
HO0119
A
2
- 12 -
B
A
R
S
L
ETAINING
CREW
OCATION
B
HD0291